Verified OSP-002 Exam Dumps PDF [2023] Access using PrepPDF [Q58-Q83]

Share

Verified OSP-002 Exam Dumps PDF [2023] Access using PrepPDF

Try Best OSP-002 Exam Questions from Training Expert PrepPDF


BICSI offers a range of resources to help candidates prepare for the OSP-002 exam. These resources include study materials, online courses, and instructor-led training. Candidates can also attend BICSI conferences and events to network with other OSP professionals and learn about the latest trends and technologies in the industry.


BICSI OSP-002 (BICSI Outside Plant Designer (OSP)) Certification Exam is a professional certification program that is designed for individuals who are interested in becoming qualified outside plant designers. BICSI Outside Plant Designer (OSP) certification is awarded by the Building Industry Consulting Service International (BICSI), a professional association that is focused on advancing the information and communications technology (ICT) industry. The OSP-002 certification is recognized globally and is highly valued by employers in the ICT industry.

 

NEW QUESTION # 58
Why are punchdown blocks used with Cat 3 and Cat 5 cabling?

  • A. Terminate cables from equipment
  • B. Interconnect cables in a telecom closet
  • C. Change from T568A to T568B terminations
  • D. Meet EIA/TIA 568 Standards

Answer: B


NEW QUESTION # 59
For a cable tray installed within an ER, the RECOMMENDED access headroom is:

  • A. 152 mm (6 in).
  • B. 254 mm (10 in).
  • C. 203 mm (8 in).
  • D. 305 mm (12 in).

Answer: D


NEW QUESTION # 60
Wireless networks require cables to connect the server, router or hub to the \_\_\_\_\_\_.

  • A. Uplink
  • B. PC
  • C. SNMP
  • D. AP (Access point)

Answer: D


NEW QUESTION # 61
The development of _________ provided a low cost cabling alternative for networks.

  • A. IBM Type 1 cable
  • B. Balanced transmission on UTP cabling
  • C. CATV coax

Answer: B


NEW QUESTION # 62
An older fiber design with a 50/125 micron core is now being used in cabling systems because it___________.

  • A. Can be cabled in more compact cable designs
  • B. Costs half as much as other multimode fibers
  • C. Has a higher bandwidth with laser sources which gives more distance capability with gigabit (and above) networks
  • D. Excess supplies are currently available from the far east

Answer: C


NEW QUESTION # 63
Does a jack have the same color code for the pairs as a punchdown block?

  • A. Depends on whether it is T568A, T568B or USOC
  • B. Depends on the type and manufacturer of the jack
  • C. No
  • D. Yes

Answer: C


NEW QUESTION # 64
When terminating Cat 5e/6, what must be remembered to maintain the performance of the installed cable?

  • A. The jacket of the cable must not be stripped back more than 3 inches
  • B. Keep the pairs twisted to within 1/2 inch of the termination
  • C. Do not strip insulation off the wires
  • D. The punchdown tool must cut off the wires close to the end

Answer: B


NEW QUESTION # 65
Structured cabling standards call for a maximum length of UTP cable for voice (POTS) of \_\_\_\_\_\_\_\_\_\_.

  • A. 100 meters
  • B. 800 meters
  • C. 90 meters
  • D. 300 meters

Answer: B


NEW QUESTION # 66
Information on the safety of chemicals used in fiber optics are __________.

  • A. Available from National Institutes of Health
  • B. In MSDS sheets supplied by manufacturers
  • C. Required to be in every installer's tool kit
  • D. Rarely useful

Answer: B


NEW QUESTION # 67
Multiple Response: Identify one or more choices that best complete the statement or answer the question.
The bandwidth and distance capability of optical fiber means that __________. (choose all that apply)

  • A. Less maintenance is required
  • B. Fewer repeaters are needed
  • C. Less power is consumed by the network
  • D. Fewer cables are needed

Answer: A,B,C,D


NEW QUESTION # 68
To maintain rated performance, twists in each pair must be maintained to within \_\_\_\_\_\_\_ of the termination.

  • A. 1/2 inch or 13 mm
  • B. 1 inch or 25 mm
  • C. 3 in or 75 mm
  • D. 2 in or 50 mm

Answer: A


NEW QUESTION # 69
Standard UTP (unshielded twisted pair) copper cabling for voice and data installations has how many pairs of wire?

  • A. Three
  • B. Two
  • C. Four
  • D. Twenty-five

Answer: C


NEW QUESTION # 70
The common IEEE 802.11b wireless LAN is also called

  • A. WiFi
  • B. WiMax
  • C. Hot Spot
  • D. Bluetooth

Answer: A


NEW QUESTION # 71
Which of the following fiber specifications is most important to the user and is an important factor in testing?

  • A. Bandwidth
  • B. Core-cladding concentricity
  • C. Attenuation
  • D. Numerical aperture

Answer: C


NEW QUESTION # 72
Which one of the following performance requirements are not shared by connectors and splices?

  • A. Durability under repeated matings
  • B. Low back reflection
  • C. Repeatability
  • D. Low loss

Answer: A


NEW QUESTION # 73
Structured cabling standards call for a maximum length of multimode fiber optic cable for backbones of
\_\_\_\_\_\_\_\_\_\_.

  • A. 2000 meters
  • B. 800 meters
  • C. 3000 meters
  • D. 1000 meters

Answer: A


NEW QUESTION # 74
What is the MINIMUM lighting requirement for telecommunications spaces?

  • A. 200 lux (18.6 foot-candles) of lighting in the horizontal plane and 500 lux (46 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
  • B. 500 lux (46 foot-candles) of lighting in the horizontal plane and 500 lux (46 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
  • C. 500 lux (46 foot-candles) of lighting in the horizontal plane and 200 lux (18.6 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
  • D. 50 lux (4.6 foot-candles) of lighting in the horizontal plane and 20 lux (1.9 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor

Answer: C


NEW QUESTION # 75
What UTP installation tool is needed for teminating most Cat 5e/6 jacks?

  • A. Punchdown tool with 66 blade
  • B. Spudger
  • C. Punchdown tool with 110 blade
  • D. Crimper

Answer: C


NEW QUESTION # 76
Copper networks can be converted to fiber optics using \_\_\_\_\_\_\_\_\_\_.

  • A. Patch panels
  • B. Fiber hubs
  • C. Rewiring
  • D. Media converters

Answer: D


NEW QUESTION # 77
The loss of a fiber optic connector is defined as _____?

  • A. The calculated loss due to geometric misalignment
  • B. The loss of the connector mated to another connector
  • C. The loss of a statistical sample of connectors
  • D. One-half the loss of a mated pair of connectors

Answer: B


NEW QUESTION # 78
Loss of a fiber or any fiber in a cable is measured in __________.

  • A. dB
  • B. milliwatts
  • C. dBm

Answer: A


NEW QUESTION # 79
Multimode graded-index glass fiber optic cables are tested with \_\_\_ sources at \_\_\_\_\_\_ and \_\_\_\_\_ wavelengths.

  • A. Laser, 1310, 1550 nm
  • B. LED, 850, 1300 nm
  • C. Laser, 980, 1400 nm
  • D. LED, 650, 850 nm

Answer: B


NEW QUESTION # 80
A wireless antenna is also known as a \_\_\_\_\_\_\_\_\_\_.

  • A. Wireless router
  • B. Hot spot
  • C. WC (wireless cell)
  • D. Access point

Answer: D


NEW QUESTION # 81
What do Category 3, Category 5e and Category 6 designations mean?

  • A. How far the cable will work in networks
  • B. Flame retardance of the cable
  • C. How well the cables are made
  • D. The performance level of UTP cable

Answer: D


NEW QUESTION # 82
What is a RJ-45 connector?

  • A. The connector used only with Cat 5e/6 jacks
  • B. A special high frequency connector
  • C. A trade name
  • D. A modular 8 pin connector with USOC pinout

Answer: D


NEW QUESTION # 83
......


The OSP-002 certification exam is administered by BICSI, a professional association for the information and communications technology (ICT) industry. BICSI is recognized globally as a leading provider of training, certification, and education for ICT professionals. The OSP-002 certification is an important credential for professionals seeking to advance their careers in the telecommunications industry and is widely recognized as a standard of excellence in outside plant design. By obtaining the OSP-002 certification, individuals can demonstrate their expertise and commitment to quality to employers and clients alike.

 

Latest 100% Passing Guarantee - Brilliant OSP-002 Exam Questions PDF: https://passcertification.preppdf.com/BICSI/OSP-002-prepaway-exam-dumps.html